UPS management checklist


Liebert Corp.
03.29.2005
Rating: -4.21- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


Regulatory compliance has become a legal and necessary extension of business continuity and disaster recovery planning. IT departments need to take steps to ensure their companies do not run afoul of an increasingly complex set of laws and regulations relating to data integrity and availability.

Therefore, managers must have a keen understanding of the regulatory compliance issues that impact business continuity planning and just as important--how mission-critical power, cooling, and monitoring strategies support business continuity.

Here are some consideration for determining the adequacy of your power and cooling protection.

1. If you rely on backup generators, is your generator sized adequately to power the cooling system and critical computer systems?

It may seem basic, but ensure that not only your critical computer systems, but your cooling systems, are supported by back-up generators. With the densities of today's computer systems, computer rooms can heat up fast if computers continue to operate on backup power without precision cooling. Also, be sure your automatic transfer switch is configured so that the lag time between switching from generator back to utility is short enough not to disrupt UPS power to your computer systems.

2. Is mission-critical network equipment— whether in the data center or at remote locations— being protected by line-interactive UPS systems?

If so, your network may be at risk. Liebert recommends against using line-interactive UPS systems for mission-critical applications. Line-interactive UPS units are only 85% effective against power anomalies in general and have little protection against surges, harmonics and frequency variations. In high-speed networks, some Liebert customers have found that in going to battery, line-interactive UPS systems drop loads, resulting in data losses. Use of double-conversion on-line UPS systems ensures continual power conditioning and maximum protection against even daily power anomalies.

3. Are you relying on UPS batteries to ride through daily power fluctuations?

If you are using line-interactive UPS units, these units go to battery every time a power anomaly occurs, which wears down the batteries more quickly than the batteries of double-conversion UPS systems. Perform a cost-benefit analysis, including battery replacement costs, for switching to double-conversion online UPS systems, which do not go to battery as often.

4. Are your UPS batteries fully charged and do you have a testing and replenishment plan in place?

It sounds elementary, but many IT managers do not know the status of their UPS batteries. Be sure to implement a policy of regular battery inspections, and have a replacement program that makes replacement manageable. Ten Questions to Ask

5. Have you performed an analysis of your power protection strategy to ensure that you are not sacrificing reliability as you build out your network?

Building redundancy into the power system is a proven strategy for increasing power system reliability and, consequently, network availability. Redundancy enables maintenance of a UPS module without affecting power to connected equipment and also increases fault tolerance.

Redundancy is typically achieved though either an N + 1 or a 1 + 1 design. In an N + 1 design, also known as a parallel-redundant system, multiple UPS modules are sized so that there are enough modules to power connected equipment (N), plus one additional module for redundancy (+ 1). During normal operation, the load is shared equally across all modules. If a single module fails or must be taken offline for service, the system can continue to power connected systems.

In a 1 + 1 design, two UPS modules are sized so that either module is capable of carrying the entire load. While 1 + 1 systems deliver a significant improvement in availability over N + 1 systems and are regularly specified for the most critical applications, N + 1 remains a viable and popular option for applications seeking to balance cost, reliability and scalability. However, a statistical analysis of the projected reliability for multi-module systems reveals the point at which the risks of power system scalability to network availability clearly outweigh the benefits.

Downtime attributed to additional modules remains fairly flat — and acceptable for many applications — up to the 3 + 1 level. At 4 + 1 and beyond, power system availability begins to drop dramatically and downtime increases substantially for each module added.

For instance, if UPS reliability is .9995, a 13+ 1 architecture will be down about 90 times as often as a 1 + 1 system. This is particularly problematic because modules are added to an N + 1 system as the load increases. Typically, a load increase correlates with an increase in network criticality. So, a "scalable" N + 1 architecture is actually responding to an increase in network criticality by reducing system availability. Ten Questions to Ask

6. Are you monitoring for heat and humidity in critical computer areas, including small rooms and server closets?

Temperature increases of 10 degrees above 75 degrees F reduce the lifespan of network equipment by 50%, and heat is the biggest threat to UPS battery life. Yet, heat density is becoming a bigger issue, as more and denser equipment is packed into small spaces. Without temperature and humidity monitoring these spaces are at risk of overheating and the downtime that may result. Small-space precision cooling solutions can help you overcome these risks.

7. Is there sufficient circulation of air to cool the computer systems area and the UPS system room, especially if you are using blade servers or other high-density equipment?

The use of blade servers has increased heat densities in data centers and computer rooms. When heat densities approach 100 watts per square foot, it's time to consider spot cooling systems to resolve hot spots. Also, ensure that you have proper air circulation and configurations to help resolve these increased densities. The rule of thumb for cooling computer equipment is one air change per minute. Do not allow hot air from computer systems to be forced back onto the computer systems or the device can ultimately be damaged. Racks should be configured in a hot aisle / cold aisle arrangement to ensure that cold supply air is directed to the cold aisle through perforated tile or an overhead system.

8. Do you have dual UPS units for all network equipment that has dual power supplies?

Network equipment manufacturers specify that their dual power supplies are for dual UPS units to ensure redundancy. Some equipment requires that both power supplies be used for the equipment to operate, and some equipment has three power supplies and requires two for operating.

There are several ways to protect this equipment. You may want to use a different UPS for each power supply and provide separate circuits for each UPS. You may also want to run communications software between dual UPS units supporting a single load to ensure that if one UPS goes down, the other UPS will continue to support the load and not initiate a graceful shutdown if not desired. Ten Questions to Ask

9. Can you keep mission-critical loads online while doing UPS maintenance?

Even in applications where UPS redundancy is not feasible, solutions are available that allow mission-critical systems to continue to operate during UPS maintenance. A maintenance bypass switch provides the capability to switch mission-critical loads to utility power during UPS maintenance.

10. Is your UPS monitoring application set to notify you when the load has exceeded 80% of the UPS system's maximum capacity?

Many IT professionals prefer to set alarms to trigger when loads reach less than 80% of capacity. Above this threshold, the UPS system may be forced to go to unplanned bypass. To avoid this, reallocate power or add power equipment as necessary instead of resorting to an unplanned transfer to bypass.
From the white paper: Regulatory Compliance and Critical System Protection: The Role of Mission-Critical Powerand Cooling in Ensuring Data Integrity and Availability, Developed by Liebert Corp. with the assistance of Network Frontiers.

Rate this Tip
To rate tips, you must be a member of SearchDataCenter.com.
Register now to start rating these tips. Log in if you are already a member.


Submit a Tip




Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


RELATED CONTENT
Data center backup power
Uninterruptible power supply load bus synchronization: Yes or no?
Do dual-power supply servers increase redundancy?
Flywheel UPS, not batteries, for data center company's backup power
Data center shaves 10% off yearly electric bill
Weighing centralized versus modular UPS in the data center
Uptime Institute warns against tier standard misuse
UPS maintenance outage
More on power supplies
Dual power question
Bob McFarlane: Blogs and more

Uninterruptible power supply management
Data center power backup isn't just about batteries anymore
How to figure size requirements for new UPS unit
UPS -- it's NOT uninterruptible
Concurrent maintainability -- your best insurance policy
Will bad batteries be your undoing?
Preventing data center power failures
How to test your UPS

Data Center Management Advisory Newsletter
ASHRAE data center infrastructure book eases bad vibrations
Green data centers are about money, not the environment
Data center facility control systems
APC launches data center infrastructure monitoring software
Google's Iowa data center smart move, experts say
Data center humidity levels source of debate
ITIL v3 launches with focus on IT service management
AFCOM special report
Lights out management: How to administer servers from the Bahamas
Rackable Systems introduces portable data center

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
uninterruptible power supply  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.

HomeNewsTopicsITKnowledge ExchangeTipsBlogsWebcastsWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Reprints  |  Site Map




All Rights Reserved, Copyright 2005 - 2008, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts