How will ultra-low sulfur diesel affect data center generator performance?


Bob Doherty, Contributor
09.08.2009
Rating: -4.33- (out of 5)


IT infrastructure news
Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google


The Environmental Protection Agency (EPA) is partly responsible for a revolutionary transformation of the diesel engine industry by mandating cleanup of diesel fuel. The program was a tiered implementation of standards to gradually reduce the sulfur content in diesel fuel from more than 3,000 parts per million (ppm) down to 15 ppm in ultra-low sulfur diesel (ULSD) fuel. Almost every country worldwide is participating, and there is promise that this will benefit the planet through avoidance of millions of tons of harmful diesel emissions.

Most of the attention to ULSD is going in the direction of the green initiative and how wonderfully clean diesel has become. For those of us working in the data center industry, USLD poses a low-probability threat to uptime, but there may be a high degree of fallout if failure occurs.

The process to refine diesel into ULSD affects the chemical properties of the product. The upsides of this process, known as hydro treating:

  • Removes sulfur
  • Virtually eliminates aromatic properties
  • Diminishes lubricity
  • Lowers conductivity
  • Reduces energy density

The possible downsides of hydro treating:

  • Increases fuel leaks
  • Reduces conductivity
  • Lowers economy
  • Extends drain intervals
  • Raises fuel cost

Potential risks of ULSD in the data center
Leaks. ULSD could cause injector fuel pump leaks and O-ring failure. Aged seals may shrink, and if there is reduced elasticity in seals they may not adapt to the change to ULSD.

Reduced lubricity. The fuel system is negatively impacted and there seems to be an increase of particulate matter. There is a known clogging of fuel filters when ULSD is introduced. Some fuel injector and fuel pump failures may be attributed to the new product as well.

Conductivity. ULSD has less conductivity than conventional diesel. With lower conductivity, it is more likely to collect an electric charge. Facility managers need to be assured that proper grounding is done during fuel delivery.

Reduced energy. There is less BTU in ULSD and less power will result. There is also a reduction in MPG.

Increased cost. The EPA says the added cost of production for ULSD is about 7 cents per gallon, while my consumer survey reveals 20 to 25 cents per gallon by the time it is dispensed at the pump.

Most of the attention to ULSD is about how clean diesel has become. For those of us in data centers, there may be a high degree of fallout if failure occurs.

Please know that the problems presented are not absolute in nature. The fact is that failures were seen across the country in different climates and in a variety of equipment. The researchers have not pinpointed specific equipment manufacturers, models or climate conditions to aid in identifying specifics, although colder climates may see a higher rate of incidents. It is clear that the introduction of ULSD had caused these difficulties, which are well beyond what is normally seen in the many industries reporting problems with ULSD use.

There is a new game in town -- it is about efficiency, energy conservation and a green initiative. Your data center emergency generator has new fuel -- it is less powerful than the old fuel, it offers reduced lubricity, there are new opportunities for failure and you get less MPG than you are accustomed to. ULSD can reduce the response time of your data center's emergency generator by as much as 5% when called to take over near-capacity loads in emergency situations. Consider the history of your generator repairs, maintenance record, the credentials of your service provider and the age of your emergency generator. Refineries are trying to compensate for many of these concerns by formulating new additives, but this continues to be a learning experience.

It's expected that the U.S. market will distribute about 60 billion gallons of ULSD in 2010. The market consists of about 70% highway diesel use, 6% railroad and marine use, 14% home use, and the remaining 10% for non-road use. The data center user community sits someplace within the non-road use. I present this because it has been difficult to draw attention to such a small piece of the pie.

Some crucial takeaways from this include the need for a heightened awareness of grounding safety during fuel delivery; increased diligence in visual inspections of your emergency generators -- especially for fuel leaks, checking and replacing filters and spare filter availability; and the importance of knowing the contents of your fuel tank, understanding the additives used, and testing emergency generators. I suggest block-load and step-load testing, and retro-commissioning will check the performance of your emergency generators. ULSD is a grand opportunity to validate the performance of the emergency generators that support your data center.

ABOUT THE AUTHOR: Bob Doherty makes it clear that he is not an engineer -- he is a data center manager with more than 40 years of experience. He is the founder and president of OMS in Your Data Center LLC, which primarily focuses on data center energy conservation best practices. Send Bob an email at BobD@ComputerRooms.com and check out ComputerRooms.com.

What did you think of this feature? Write to SearchDataCenter.com's Matt Stansberry about your data center concerns at mstansberry@techtarget.com.

Rate this Tip
To rate tips, you must be a member of SearchDataCenter.com.
Register now to start rating these tips. Log in if you are already a member.




BROWSE BY TAG
Data center design and facilities,   Data center backup power and power distribution,   Data center disaster recovery,   Data Center Management Advisory Newsletter,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google



RELATED CONTENT
Data center backup power and power distribution
Data center 2009 Products of the Year award winners
Data center flywheel gets thumbs-up from colo provider
Data center efficiency: Which tactics are worth the cost?
IBM VMworld news in brief
How to choose the right uninterruptible power supply for your data center
Avoid common pitfalls when calculating data center power load
In measuring data center power use, more (info) is more
The TPC Energy Specification: Energy consumption vs. performance and costs
Measuring data center energy consumption in watts per logical image
Data center managers plan for power density jumps
Data center backup power and power distribution Research

Data center disaster recovery
Data center flywheel gets thumbs-up from colo provider
Data center pros must prepare for increased space weather
Are you wasting disaster recovery budget to avoid employee inconvenience?
Uptime Institute opens data center availability tiers
Four ways to extend data center UPS battery life
Why SunGard uses flywheel UPSes in its data centers
Lower disaster recovery costs with open source replication tools
Apple updates Xserve, Symantec ships DR monitoring software: News in brief
Data center disaster recovery planning
Google opts for battery backup over UPS: News in brief
Data center disaster recovery Research

Data Center Management Advisory Newsletter
New security technologies tighten data center access control
Data center outsourcing best practices and pitfalls to avoid
Data center pros must prepare for increased space weather
Data center consolidation strategy can benefit from ITIL lifecycle
Sizing computer room air conditioners for data center energy efficiency
Data center humidity levels source of debate
Where and how to build your next data center in a down economy
Avoid data center relocation failure: Top five pitfalls
Understanding green IT and data center energy-efficiency regulations
Preventing a data center power crisis

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
Electric plugs for each country  (SearchDataCenter.com)
green data center  (SearchDataCenter.com)
intelligent power management (IPM)  (SearchDataCenter.com)
power usage effectiveness (PUE)  (SearchDataCenter.com)
uninterruptible power supply  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.



White Papers - Data Center Networking

The Intel IT Technology Center - Power, Performance and Mobility Solutions

HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2010, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts