Rules for designing the urban data center


Carrie Higbie
04.12.2005
Rating: -2.80- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


A data center design problem that often gets overlooked is building or renovating in an existing building in an urban area. There are specific and unique physical requirements, as well as obstacles, that people planning data centers need to address. While building a data center in an already heavily populated area creates a slew of problems, it's not impossible to overcome. There are a few basic guidelines to consider before you start, however.

1. Be aware that according to TIA-942, cabling must be run accommodating growth so that you don't have to revisit your horizontal. This means that you have to cable for today's needs and what you anticipate in the upcoming future. This means that you want to cable for application speeds that you will use within the next 10 years - so 10Gig system will certainly come into play in that period of time.

2. Be sure that you are compliant with local codes and have all abandoned cable removed prior to starting. Abandoned cable is any cable that is not terminated at both ends or not marked for future use. It is in your best interest to have all of this out of your way before you start adding your own cable. Excess abandoned cable will restrict air flow, can cause additional fuel loads of there is a fire, etc.

3. Check with your carriers to determine if the conduits running to the building will accommodate whatever circuits you will need. This can be a VERY expensive gotcha if you don't check and have to pay for directional core bores or drilling under existing roadways.

4. Check for local ordinances and codes for fire suppression and cable coating requirements (for instance does it have to be limited combustible, run in conduit, etc.)

5. Heating and cooling will be particularly important. If you will be incorporating blade servers into your data center the HVAC requirements will increase.

6. Check for seismic requirements, floor loading, etc.

7. Check with the power companies for redundancy options. This could be a problem if you are not able to get redundant circuits, it may change your generator capabilities.

8. Make sure that fire hydrants are close and the fire department does not have to cross railroad tracks to get to you as it will affect your insurance rates.

9. Look for physical barrier security - for instance, will you need to add barriers to keep people from accidentally driving through the building. What are your security options?

10. Beware of floor loading as well. Some high rise buildings can not support data center equipment without very expensive structural fortifications and modifications.

About the author. Carrie Higbie is the global network applications market manager for The Siemon Company and has been involved in the computing and networking industries for nearly 20 years. She has worked with manufacturing firms, medical institutions, casinos, healthcare providers, cable and wireless providers and a wide variety of other industries in both networking design/implementation, project management and software development for privately held consulting firms and most recently Network and Software Solutions.

Rate this Tip
To rate tips, you must be a member of SearchDataCenter.com.
Register now to start rating these tips. Log in if you are already a member.




Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


<< PREVIOUS | NEXT >>: Bad location puts data center security at risk
VIEW ALL IN THIS CATEGORY

RELATED CONTENT
Data center network cabling
Data center managers' holiday wish lists
Data center cable labeling standard 606a ain't all that
Cisco and QLogic execs mull IDC's InfiniBand forecast
Cable remediation in the data center
HP BladeSystem option simplifies server provisioning
How to determine data center cabling requirements
Calculating costs of data center cabling infrastructure
Overheating servers
Best practices: A guide to cable management
Quiz: Got cabling?
Data center network cabling Research

Data center room design and location
New ADC data center a model of energy efficiency, design
HP's POD: The newest containerized data center
Data center tour: Equinix shows off its upside down data center
IBM to sell building-block, containerized data centers
The Planet's Jeff Lowenberg named Data Center Manager of the Year
Data center saves $700K renovating DR site and severing SunGard contract
Terremark data center manager puts all skills to work
Prepping data centers for a hot summer
Can CFD modeling save your data center?
Data center cooling optimization in the virtualized-server world
Data center room design and location Research

Infrastructure Management Tips
DC Pro: a breakdown of a data center efficiency tool
Data center construction runbook -- Chapter 3: Selecting a general contractor
Data center construction runbook, Chapter 2: Selecting a winning data center design team
Protecting your data center from real show-stoppers: Preparing a disaster recovery plan
Economizer performance: Applying CFD modeling to the data center's exterior
Data center construction runbook -- Chapter 1: Data center site selection
ASHRAE data center infrastructure book eases bad vibrations
United Parcel Service's Tier 4 data center goes green
Green UPS Tier IV data center water-side economizers
Do dual-power supply servers increase redundancy?

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
liquid-tight strain-relief connector  (SearchDataCenter.com)
raceway  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.

HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Reprints  |  Site Map




All Rights Reserved, Copyright 2005 - 2008, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts