Data center standards


Carrie Higbie
02.23.2004
Rating: -3.29- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


With a slew of standards updates and regulation changes all your free time could be spent pouring over documentation. In an attempt to shorten the curve and provide information on impact, we have developed a short course that will be published in sections. This first course covers one of the most notable standards that is expected to be published in October 2004 -- TIA's new data center standard TIA/TR 942. This new standard addresses compartmentalization within the data center, the tier and redundancy levels developed by the Uptime Institute. Data centers are divided into the actual data center/computer room where supporting devices reside and where power and telecommunications enter the facilities.

One of the design considerations that caught my attention was the development of hot zones within the data center. In concert with the equipment manufacturers this new design creates hot and cold zones for equipment racks. Understanding that equipment pulls cool air from the front and discharges hot air to the back, new rack placement layouts call for cold aisles (the front of one piece of equipment facing the front of another piece of equipment) and hot aisles where the backs of the equipment share a like aisle. This keeps any one piece of equipment from drawing the heated air of another.

Another key consideration is the call for all horizontal cables to be run in sufficient number to account for growth such that the horizontal cables should not have to be "touched" again after the initial installation. This can be a bit tricky in planning. However with pathways under raised floors, overhead cable trays and cabling within the racks, revisiting these areas has the potential to knock down services for equipment that is running on the existing cable. It is generally less expensive to run all of the cables at once than it is to coordinate moves, adds and changes (MACs) at a later time. The standard recommends a minimum of two outlets at each work area, and of course, these have to be terminated within the equipment distribution areas. Additional cables for devices such as wireless access points, IP video cameras and building automation systems should also be planned and terminated.

The National Fire Protection Association (NFPA) is also involved in data centers standards and authors three standards that impact data center design. The first, and most widely known is the NEC or National Electrical Code. The NEC addresses fire and safety issues. This includes things such as plenum areas, fire, life and safety systems, etc. Two other parts of the NEC that are applicable include NFPA13, NFPA90A. NFPA 13 governs the installation of sprinkler systems and states that if there are combustibles within the plenum space (any space with return air) that not only does the room need to be sprinkled, but the plenum area likewise must be sprinkled. Installation of air conditioning and ventilation systems falls under NFPA 90A.
MORE INFORMATION
This white paper published by Siemon is designed to provide you with a basic roadmap for your data center.

Here's a link to a DuPont video regarding Teflon FEP

Dupont has developed a new cable coating that provides far better protection in return air environments and in fact, eliminates the need to sprinkle plenum areas. The cable coating (Teflon® FEP) when applied creates a cabled called a Limited Combustible Cable or LCC. These cables burn slower and create less equipment damaging smoke than CMP cables more commonly known as plenum cable.

There are several Web sites that provide useful information on data centers and are referenced below. These sources will provide information on design, compartmentalized areas, redundancy and resiliency, and links to their events. You can also get a great explanation of the tier levels and types of data centers.


Carrie Higbie, Global Network Applications Market Manager, The Siemon Company
Carrie has been involved in the computing and networking industries for nearly 20 years. She has worked with manufacturing firms, medical institutions, casinos, healthcare providers, cable and wireless providers and a wide variety of other industries in both networking design/implementation, project management and software development for privately held consulting firms and most recently Network and Software Solutions.

Carrie currently works with The Siemon Company where her responsibilities include providing liaison services to electronic manufacturers to assure that there is harmony between the active electronics and existing and future cabling infrastructures. She participates with the IEEE, TIA and various consortiums for standards acceptance and works to further educate the end user community on the importance of a quality infrastructure. Carrie currently holds an RCDD/LAN Specialist from BICSI, MCNE from Novell and several other certifications.

Rate this Tip
To rate tips, you must be a member of SearchDataCenter.com.
Register now to start rating these tips. Log in if you are already a member.




Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


RELATED CONTENT
Data center standards and metrics
Computer Measurement Group teaches IT forecasting, modeling
With end-user performance management tool, credit union hones troubleshooting
DOE's new data center energy-efficiency tool on cusp of release
Uptime Institute expands data center tier rating system
EPA releases draft Energy Star server specification
Uptime Institute Data Center Design Charrette podcasts
EPA promises data center efficiency metrics for 2008
DMTF tries to SMASH systems management costs
EPA sends final report on data center energy efficiency to Congress
Change management tools become more comprehensive with ITIL v3

Data center network cabling
Data center managers' holiday wish lists
Data center cable labeling standard 606a ain't all that
Cisco and QLogic execs mull IDC's InfiniBand forecast
Cable remediation in the data center
HP BladeSystem option simplifies server provisioning
How to determine data center cabling requirements
Calculating costs of data center cabling infrastructure
Overheating servers
Best practices: A guide to cable management
Quiz: Got cabling?
Data center network cabling Research

Data center cooling
ADC data center aiming for 1.1 PUE, LEED Platinum
Oracle CIO details new Utah data center at LinuxWorld/Next Generation Data Center
Hot-aisle/cold-aisle containment and plenum strategies go big-time
IBM sells RackForce on Enterprise Modular Data Center
The Planet's Jeff Lowenberg named Data Center Manager of the Year
Companies reuse data center waste heat to improve energy efficiency
Terremark data center manager puts all skills to work
Data center cooling case studies topic of new ASHRAE book
Prepping data centers for a hot summer
The green data center 2.0: Beyond best practices
Data center cooling Research

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
ASHRAE  (SearchDataCenter.com)
CADE (Corporate Average Data center Efficiency)  (SearchDataCenter.com)
data center infrastructure efficiency (DCIE)  (SearchDataCenter.com)
data center services  (SearchDataCenter.com)
EDI  (SearchDataCenter.com)
ISO 9000  (SearchDataCenter.com)
ITIL  (SearchDataCenter.com)
Linpack benchmark  (SearchDataCenter.com)
TIA-942  (SearchDataCenter.com)
workload  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.

HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Reprints  |  Site Map




All Rights Reserved, Copyright 2005 - 2008, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts