Thinking about inline power?


Tom Lancaster
07.31.2003
Rating: --- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


The ability to provide electrical power to IP phones through the CAT5 Ethernet cable is a boon to many IP Telephony deployments. It has a number of advantages that were largely taken for granted in the old world, where the PBX has been supplying power to phones for over a century. However, there are a couple of big gotchas that you must be aware of if you're planning to use inline power.

Before we discuss some of the gotchas, you should realize that inline power is not a requirement, and many organizations are electing simply to plug their phones into local electrical outlets for power. Of course, if you lose power to the wall outlets, you lose the use of your phone, but just because the users are accustomed to the phones still working during a power outage doesn't mean it's a requirement for your project. Each organization needs to determine this individually.

The first gotcha we'll mention is that your cabling may or may not be an issue. Ethernet only requires two pairs of the four provided in the various wiring specifications, so many organizations either never punched down pairs 3 and 4, or are using some legacy cabling like IBM's Type-1, which they kept from when Token Ring was deployed. Power over Ethernet can work with these types of cables... but here's the catch. Inline power delivered directly from a switch uses the same pairs (1 and 2) as Ethernet, so there's no problem. However, if you're using one of the powered patch panels, they deliver power over pairs 3 and 4, and if they're not punched down, inline power isn't an option for you. Consider this before you spend tens of thousands on powered patch panels.

The second gotcha to mention is that many organizations don't have a UPS in their closets. If their network equipment loses power, their phones are dead anyway, whether they're using inline power or not. Also, some companies have UPSs in their wiring closets, but not enough. Newer switches with inline power have far greater requirements than their predecessors. For instance, a popular Cisco switch supporting 240 phones has 2500W power supplies. This can quickly overrun a UPS that was previously sufficient.


Thomas Alexander Lancaster IV is a consultant and author with over ten years experience in the networking industry, focused on Internet infrastructure.


Rate this Tip
To rate tips, you must be a member of SearchDataCenter.com.
Register now to start rating these tips. Log in if you are already a member.




BROWSE BY TAG
Data center network cabling,   Data center design and facilities,   Data center backup power and power distribution,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
Data center network cabling
Data center cabling management: Mind over matter
Should you comply with Article 645 of the National Electrical Code?
IBM tightens ties with Cisco rival Brocade: News in brief
IBM/Brocade deal reeks of Cisco hostility
A data center relocates on New Year's Eve
Dell/Cisco partnership may simplify data center infrastructure
27 tips for good data center design
Bank refreshes outdated data center with PDUs, new CRAC units
PDU Cables showcases new offerings
Data center managers' holiday wish lists
Data center network cabling Research

Data center backup power and power distribution
Data center 2009 Products of the Year award winners
Data center flywheel gets thumbs-up from colo provider
Data center efficiency: Which tactics are worth the cost?
How will ultra-low sulfur diesel affect data center generator performance?
IBM VMworld news in brief
How to choose the right uninterruptible power supply for your data center
Avoid common pitfalls when calculating data center power load
In measuring data center power use, more (info) is more
The TPC Energy Specification: Energy consumption vs. performance and costs
Measuring data center energy consumption in watts per logical image
Data center backup power and power distribution Research

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
liquid-tight strain-relief connector  (SearchDataCenter.com)
raceway  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.



White Papers - Data Center Networking

The Intel IT Technology Center - Power, Performance and Mobility Solutions

HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2010, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts