Green Grid tool assesses free cooling potential

By Mark Fontecchio, News Writer
09 Apr 2009 | SearchDataCenter.com

IT infrastructure news
Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google

The Green Grid now offers an online calculator to help data center managers determine how much free cooling they can get.

For more on data center cooling:
Data center cooling news

Cooling data center with outside air gets the go-ahead

Data center liquid cooling vs. forced air cooling

Free cooling comes in the form of air-side and water-side economizers. With air-side economizers, often called fresh-air cooling, outside air is taken into a data center, usually filtered, and then used to cool the IT equipment. With water-side economizers, the outside air cools water in the outside chiller or water tower, which in turn cools a data center.

Both methods have become popular to reduce the electricity costs associated with mechanical refrigeration. Data center giants Google and Microsoft use free cooling where possible, and even smaller operations can use it to their advantage.

Calculating the payoff
Canadian media company Quebecor Inc., for example, cools its 2,500-square-foot data center with air-side economizers. The economizers include baffles that open to varying degrees depending on the outside temperature and how much cooling a data center needs as well as three filters that pull bacteria-sized particulates out of the air and a humidifier to condition it for IT equipment. About 10% of the waste heat produced by the servers is then re-circulated to help condition the outside air that comes into a data center.

The Green Grid's online calculator includes a series of inputs -- location, temperature and humidity thresholds, IT load, and the cost of electricity are a few -- and at the other end spits out how many hours that data center can use air-side and water-side economizers, and how much money it could save.

A data center in Chicago, for example, with a 1 MW of IT load and a power usage effectiveness (PUE) of 1.6, paying 8 cents per kilowatt-hour and falling within ASHRAE's recommended temperature and humidity levels, can expect to save $20,000 a year by using air economizers for 660 hours, or $140,000 a year using water-side economizers for 4,861 hours, which is more than half the year.

In some parts of North America, such as northern Alaska and the far-north region of the Canadian province of Quebec, data centers can get as many as 8,000 hours of water-side economizing, which is more than 90% of the year. Other areas such as Miami, however, can only get 1,000 or fewer hours of water-side economizing.

The Green Grid, a nonprofit group, also created maps of North America with rough approximations of how many hours of economizing data centers can achieve in each location (fresh-air cooling image here, and water-side cooling image here). The free versions appear at a smaller resolution than the larger versions available for Green Grid members who want more detail.

"Fresh-air cooling and water-side economizers have become more popular," said Mark Monroe, a member of the Green Grid's board of directors and the director of sustainable computing at Sun Microsystems Inc. "This gives people a simple tool to get a quick estimate of how much free cooling they might be able to get with their data centers."

Let us know what you think about the story; email Mark Fontecchio, News Writer.

Also, check out our data center blogs: ; Server Farming, Mainframe Propellerhead, and Data Center Facilities Pro

.

Tags: Data center coolingData center power consumption and savingsVIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google



RELATED CONTENT
Data center cooling
IT wish list: Better ways to analyze data center environmental metrics
End users still cool on Iceland as a data center site
Air-side economizers reduce energy use at NetApp data center
Sizing computer room air conditioners for data center energy efficiency
Should you comply with Article 645 of the National Electrical Code?
How to identify and remediate data center hot spots
Data center humidity levels source of debate
Air-side and water-side economizers in the data center
Amazon data center facility engineer touts radical cooling tactics
Colo taps cold weather, river for green data center
Data center cooling Research

Data center power consumption and savings
IT wish list: Better ways to analyze data center environmental metrics
Data center colo scores energy rebates for UPS and more
Buyout could boost Uptime Institute
End users still cool on Iceland as a data center site
Reporter's notebook on AFCOM Data Center World: Day two
Notes from AFCOM Data Center World: Day one
U.S. versus global data center trends: IT priorities vary
Hot-aisle/cold-aisle containment takes hold
SPECpower benchmark has flaws, says analyst
The Green Data Center: Energy-Efficient Computing in the 21st Century

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
ambient temperature  (SearchDataCenter.com)
ASHRAE  (SearchDataCenter.com)
Calibrated Vectored Cooling  (SearchDataCenter.com)
compaction  (SearchDataCenter.com)
computer room air conditioning unit  (SearchDataCenter.com)
data center chiller  (SearchDataCenter.com)
green data center  (SearchDataCenter.com)
hot/cold aisle  (SearchDataCenter.com)
HVAC  (SearchDataCenter.com)
water cooling  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary



Efficient Management for Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts