Data center cooling: Air-side and water-side economizers

By SearchDataCenter.com
29 Sep 2008 | SearchDataCenter.com

IT infrastructure news
Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google

Air- and water-side economizers can provide energy savings in data centers. SearchDataCenter.com has been following the evolution of this technology that was once seen as infeasible for data centers to its acceptance, implementation, and optimization. By definition an economizer is a mechanical device used to reduce energy consumption. With rising energy costs, data center managers are increasingly focused on efficient cooling options for data centers.


Used with permission, © 2008 E Source Companies LLC.

TABLE OF CONTENTS
I. The evolution of data center air-side and water-side economizers
II. Data center air-side and water-side economizer case studies
III. Improving economics and performance of data center economizers

I. The evolution of data center air-side and water-side economizers

Will liquid cooling work for high-heat producing hardware?
Innovation is paving the way for technologies that may enable the IT market to finally deliver true liquid-cooled solutions that are both energy efficient and cost effective.

Fears of cooling with outside air may be unfounded
The fears of contaminants in outside air and the impact of humidity on equipment were the focus of a study by the Lawrence Berkely National Laboratory in 2006.

ASHRAE expands recommended server temperature and humidity range
Setting the ground work for air-side economizer cooling systems, in the fall of 2007 the American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE) announced that it was expanding its recommended specifications for server temperature and humidity ranges.

Cooling data centers with outside air gets the go-ahead
The Lawrence Berkley National Laboratory study found that using air-side economizers to cool the data center is safe for IT equipment and lowers the overall power costs.

The green data center 2.0: Beyond best practices
Incremental data center energy-efficiency improvement will not meet increasing demand for power. The cooling challenge requires IT professionals to move beyond standard data center design memes of raised floors and hot aisle/cold aisle containment.

Data center energy a concern, but metrics lacking
Data centers managers are concerned about energy efficiency and taking steps to fix it, according to the 2008 SearchDataCenter.com Purchasing Intentions Survey. But many are unclear on how much these efforts have actually reduced costs.

The Google pirates, corporate tax, and ice-side economizers
Google file a patent for a water-based data center, taking the concept of liquid cooling to its extreme.

II. Data center air-side and water-side economizer case studies

Intel recently released a video, "Reducing Data Center Cost with an Air Economizer: An Intel Prooof of Concept" hosted by Don Atwood, Regional Data Center Manager in Intel Information Technology. Don walks you through an Intel facility in New Mexico that has tested the effectiveness of air-side econmizers side-by-side with traditional cooling systems. The 10 month test yielded pretty powerful results, including a 74% reduction in power consumption in a 10 megawatt high density (90% CPU utilization) facility. For more information, see the Intel white paper: "Reducing data center cost with an air economizer".

Green UPS Tier IV data center water-side economizers
United Parcel Service's data center facilities team in Alpharetta, Ga., have green data center operations down to a science. Learn how they did it.

Data center cooling economizers save energy costs, says Equinix
By using economizers, data center colocation company Equinix says it saves up to 80% in annual cooling costs in the eight of 19 U.S. facilities that house them.

Companies reuse data center waste heat to improve energy efficiency
Quebecor and IBM have developed innovative ways of reusing data center waste heat in an effort to lower overall energy costs. Quebecor installed air-side economizers to bring in cool air from outside, and uses the waste heat from the data center to heat adjoining rooms. IBM Switzerland is piping the waste heat to a swimming pool that formerly had formerly used heating oil.

ADC data center aiming for 1.1 PUE, LEED Platinum
Advanced Data Centers is building a data center with a power usage effectiveness value of 1.1, head and shoulders above industry standard. The company is combining technologies including air-side economizers, rotary uninterruptible power supplies (UPSes) and hot-aisle containment in their effort for data center energy efficiency.

IBM building super-efficient data center in Colorado
IBM planned a data center in Colorado with a projected power usage effectiveness value of 1.25, twice as efficient as the industry standard. The facility will take advantage of free cooling for 75% of the year using a water-side economizer.

Video of IBM's new green data center in Boulder, Colorado
A video featuring IBM's Boulder, Colorado data center released on the opening day of the facility. The data center is twice as efficient as the industry standard and uses a water-side economizer for cooling.

III. Improving economics and performance of data center economizers

Economizer performance: Applying CFD modeling to the data center's exterior
CFD modeling isn't only useful for modeling airflow within a data center, it can also improve air economizer performance external to a building. CFD modelling can visually show airflow and prevent unwanted contaminants from entering the system and your data center.

Matt Stansberry is SearchDataCenter.com's senior site editor. Write to him about your data center concerns at mstansberry@techtarget.com. And check out our Data center facilities pro blog.

ADDITIONAL RESOURCES ON AIR-SIDE and WATER-SIDE ECONOMIZERS:

Section I appendix
EPA Report on Server and Data Center Energy Efficiency
A review of ASHRAE Standard 90.1's requirements for air-side economizers and a discussion of the benefits
Hot air isolation cools high-density data centers
Economizers: Saving data center energy

Section II appendix
Wells Fargo's Minneapolis data center expects to save $450,000 annually with their air-economizer system
Results of a 10-month proof of concept study by Intel on the use of air-economizers
Intel's case study using wet side economizers
Red Rocks Data Center: Air-side economizer project page
A MechSE student design team helps save $2 million a year in data center utility costs

Section III appendix
Optimizing the use of outside air inside data centers
Utilizing economizers effectively in the data center
Mechanical air handling systems need to be optimized rather than relying on traditional air-handling set-up


Tags: Data center coolingData center power consumption and savingsData center power consumption and savingsVIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google



RELATED CONTENT
Data center cooling
IT wish list: Better ways to analyze data center environmental metrics
End users still cool on Iceland as a data center site
Air-side economizers reduce energy use at NetApp data center
Sizing computer room air conditioners for data center energy efficiency
Should you comply with Article 645 of the National Electrical Code?
How to identify and remediate data center hot spots
Data center humidity levels source of debate
Air-side and water-side economizers in the data center
Amazon data center facility engineer touts radical cooling tactics
Colo taps cold weather, river for green data center
Data center cooling Research

Data center power consumption and savings
Sizing computer room air conditioners for data center energy efficiency
IBM VMworld news in brief
Air-side and water-side economizers in the data center
How to choose the right uninterruptible power supply for your data center
Avoid common pitfalls when calculating data center power load
Amazon data center facility engineer touts radical cooling tactics
The TPC Energy Specification: Energy consumption vs. performance and costs
Measuring data center energy consumption in watts per logical image
Data center managers plan for power density jumps
Backup power in a shipping container: Active Power's PowerHouse

Data center power consumption and savings
IT wish list: Better ways to analyze data center environmental metrics
Data center colo scores energy rebates for UPS and more
Buyout could boost Uptime Institute
End users still cool on Iceland as a data center site
Reporter's notebook on AFCOM Data Center World: Day two
Notes from AFCOM Data Center World: Day one
U.S. versus global data center trends: IT priorities vary
Hot-aisle/cold-aisle containment takes hold
SPECpower benchmark has flaws, says analyst
The Green Data Center: Energy-Efficient Computing in the 21st Century

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
ambient temperature  (SearchDataCenter.com)
ASHRAE  (SearchDataCenter.com)
Calibrated Vectored Cooling  (SearchDataCenter.com)
compaction  (SearchDataCenter.com)
computer room air conditioning unit  (SearchDataCenter.com)
data center chiller  (SearchDataCenter.com)
green data center  (SearchDataCenter.com)
hot/cold aisle  (SearchDataCenter.com)
HVAC  (SearchDataCenter.com)
water cooling  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary



Efficient Management for Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts