Home > Data Center News > Terremark data center manager puts all skills to work
Data Center News:
EMAIL THIS

Terremark data center manager puts all skills to work

By Mark Fontecchio, News Writer
16 May 2008 | SearchDataCenter.com

IT infrastructure news
Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google

There's a benefit that comes with being a jack-of-all-trades, and Ben Stewart realizes this. Now the vice president of facilities engineering at data center colocation company Terremark Worldwide Inc., Stewart has also held positions within the company in commercial and federal operations, networking and security.

Data Center Manager of the Year

The Planet's Jeff Lowenberg named Data Center Manager of the Year

Logistics firm coordinates multisite data center consolidation

Terremark data center manager puts all skills to work

Data center saves $700K renovating DR site and severing SunGard contract

Stewart has put all his knowledge to work in overseeing the building of five 50,000-square-foot data center buildings on a 30-acre site in Culpeper, Va., about 90 minutes southwest of Washington, D.C.

Based in Miami, Terremark decided to build in the Beltway because it had several federal government customers that needed better access to their equipment. The first building has been constructed, with the others to be built as demand dictates.

The Culpeper site has several interesting features. First, Terremark doesn't use battery-based uninterruptible power supply (UPS) systems. Instead, it has installed 11 900-kVA flywheel UPSes.

While some worry about the reliability and ride-through time of flywheels, Terremark has used them for a while, and Stewart said the company has yet to confront a problem.

We're in the business of selling square footage, not consuming it ourselves.
Ben Stewart,
vice president of facilities engineering, Terremark Worldwide Inc.

"I don't know any data centers that can go a minute or two without cooling," he said. "If they need ride-through time for 10 or 15 minutes and they're not running their air handlers on the UPS, they're going to have to shut their stuff down anyway."

How does that translate into savings? Stewart said capital costs are similar, but he won't have to replace strings of batteries every three to five years, which can cost $100,000. Also, flywheels don't take up as much real estate as batteries. Go into a large data center that runs battery-based UPSes and you'll likely find a separate room or rooms that contain just battery strings.

"We're in the business of selling square footage, not consuming it ourselves," Stewart said.

Also at the Culpeper site, Terremark will use water-side economizers, which use the naturally cold air outside to cool the water that feeds into data center chillers. Stewart said that these are a better fit in Culpeper than in Miami, where the weather is much warmer year-round. In Culpeper, he expects to get three to four months of free cooling. For an additional month on each side, he expects to supplement the more costly mechanical refrigeration with free cooling at night.

Though Stewart isn't certain exactly how much the free cooling will save him until all the buildings have been built and filled, he said that the monthly energy bill in Miami is $630,000, and chiller costs are about 40% of that. If Culpeper's costs are similar, that could mean more than $1 million in savings every year.

Broad skill set pays off
When it comes to filling up the new Culpeper site with customers, Stewart's broad experience can help there, too.

"When I go to meetings with potential customers, I can cover full services from power densities to security to network connectivity," he said. "My background allows me to sit in a room with a customer and be able to go down the whole checklist."

For more on Ben Stewart at Terremark:
Hosting company closely monitors green data center certifications

Flywheel UPS, not batteries, for data center company's backup power

And it's not just a benefit to him. His facilities engineering staff of about a half-dozen people can capitalize on it as well.

"He has a lot of knowledge in different parts of the company," facility engineer Albert Ramos said. "He'll teach me something about part of the company that I don't have direct contact with."

In 2003, Stewart joined Terremark, after a 25-year tenure in the U.S. Coast Guard, where he got his electrical engineering degree. He also got his master's degree in electrical engineering at the Naval Postgraduate School and his master's in business administration from Monmouth University.

"He's a commanding presence," said Ed Jacobson, the president of Terremark technology contractors and Stewart's boss. "He's a bright guy and gets things quickly. With his 25 years in the Coast Guard, he's organized and is good at the rank-and-file order of things."

Let us know what you think about the story; email Mark Fontecchio, News Writer. You can also check out our Server Specs blog.



Tags: Building or renovating a data centerData center room design and locationData center coolingVIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google



RELATED CONTENT
Building or renovating a data center
Buyout could boost Uptime Institute
End users still cool on Iceland as a data center site
Data center consolidation strategy can benefit from ITIL lifecycle
Data center location selection: Incentives can tip scales
Microsoft cuts ribbon on mega data center
Big IT shops look to rent data center facilities
Key aspects of designing a data center for maintainability
Microsoft to open two mega data centers: News in brief
Hewlett-Packard demonstrates its Performance Optimized Data center (POD)
Where and how to build your next data center in a down economy

Data center room design and location
Air-side economizers reduce energy use at NetApp data center
Data center location selection: Incentives can tip scales
Notes from AFCOM Data Center World: Day one
Microsoft cuts ribbon on mega data center
Hot-aisle/cold-aisle containment takes hold
How to identify and remediate data center hot spots
Colo taps cold weather, river for green data center
Preventing particle and gas contamination in the data center
Cleaning under the raised-floor plenum: Data center maintenance basics
AMD augments six-core Opteron chip line: News in brief
Data center room design and location Research

Data center cooling
IT wish list: Better ways to analyze data center environmental metrics
End users still cool on Iceland as a data center site
Air-side economizers reduce energy use at NetApp data center
Sizing computer room air conditioners for data center energy efficiency
Should you comply with Article 645 of the National Electrical Code?
How to identify and remediate data center hot spots
Data center humidity levels source of debate
Air-side and water-side economizers in the data center
Amazon data center facility engineer touts radical cooling tactics
Colo taps cold weather, river for green data center
Data center cooling Research

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
unified computing system (UCS)  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary



Efficient Management for Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts