More perforated tiles equal better data center cooling

By Mark Fontecchio, News Writer
27 Feb 2007 | SearchDataCenter.com

IT infrastructure news
Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google

DALLAS -- When you pump cold air into a raised floor, you expect it will all arrive at its destination -- the server racks. But like a disobedient child, some of the cold air is probably sneaking off where it shouldn't, and it's costing you money.

A new study from Innovative Research Inc., a Plymouth, Minn.-based computational fluid dynamics (CFD) company, said a lot of that has to do with your perforated tiles; more specifically, how many of them you have.

More from ASHRAE Dallas
Raised floor bests overhead cooling, IBM finds

APC 'capture index' measures airflow in the data center

Liquid cooling is your friend, ASHRAE speakers say

"Distributed air leakage can represent a significant portion of the total airflow into the plenum," said Kailash Karki, vice president of research and technology, Innovative, at a recent conference in Dallas for the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

Karki estimated that air leakage could account for as much as 15% of all airflow exiting into the data center room. Not only does that waste cooling, but it also requires more power to properly cool equipment.

When installing a raised-floor environment in a data center, so-called perforated tiles (like floor vents) are dispersed among solid floor panels so that cold air flowing from computer room air-conditioners (CRACs) can rise through the floor and into server racks, cooling off hot equipment. But if the raised floor isn't constructed correctly, air can push through other unintentional openings in the floor where it isn't useful to the equipment.

There are a number of places the leaked air could enter the data center: loose cable cutouts under cabinets, spaces between floor tiles and the walls, or between poorly aligned floor tiles, missing tiles or superfluous perforated tiles.

Innovative's study describes the distributed air leakage as the total area of gaps between floor panels on a raised-floor environment. Using CFD technology, Innovative was able to determine variables, such as the flow rate under a raised floor and the flow rate leaving the floor tile, which allows them to calculate the distributed air leakage. According to Karki, many of the gaps allowing cold air leakage are tiny, some less than one millimeter.

Karki and his co-authors, Amir Radmehr and Suhas Patankar, discovered that air leakage was more prominent when the ratio of perforated tiles to total floor space was smaller. That is, fewer perforated tiles equals more air leakage.

To research the problem, the company set up a 364-square-foot minidata center with a 12-inch raised floor and no obstructions, such as water pipes, underneath. They then installed two rows of perforated tiles sitting near a CRAC unit blowing at 10,000 cubic feet per minute (cfm). The study looked at air leakage with 4, 8, 12, 16 and 20 perforated tiles.

It found that there was more than twice as much air leakage with four tiles as there was with 20.

"What we were looking for was airflow through the gaps," Karki said. "Not all of the airflow is exiting through the perforated tiles."

The solution? Try increasing perforated tiles as long as they direct cold air to the equipment, and make sure that any opportunities for air leakage are shut down.

Let us know what you think about the story; e-mail: Mark Fontecchio, News Writer, and check out the SearchDataCenter.com Blog.

Tags: Data center coolingData center room design and locationVIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google


RELATED CONTENT
Data center cooling
Hot-aisle vs. cold-aisle containment: Liebert and APC face off
Core4 sells more efficient -- and costly -- CRACs
Grow a green business: Cut costs and improve energy efficiency with green IT
At colo data center, air mixing happens up high
Intel offers data center management software: News in brief
Data Center Facilities IT Handbook
IBM tightens ties with Cisco rival Brocade: News in brief
Lowering data center cooling costs with airflow modeling and perforated raised-floor tiles
Closing the green gap: Expanding data centers with environmental benefits
Green Grid tool assesses free cooling potential
Data center cooling Research

Data center room design and location
Hot-aisle vs. cold-aisle containment: Liebert and APC face off
Core4 sells more efficient -- and costly -- CRACs
Hewlett-Packard demonstrates its Performance Optimized Data center (POD)
Schneider: IT and energy management control systems bring efficiency
Sun Microsystems releases new version of OpenSolaris
Where and how to build your next data center in a down economy
HP updates mission-critical services: News in brief
Ascent builds customizable data center hosting facility: News in brief
Data center air recycling saves cash-strapped greenhouse
At colo data center, air mixing happens up high
Data center room design and location Research

Data center design and infrastructure
Hewlett-Packard demonstrates its Performance Optimized Data center (POD)
CRG West preps data centers for cloud computing customers
Six tips for designing a cost-effective data center
Pros and cons of international data center locations
Uptime conference goers mull data center efficiency
Cooling data centers with outside air gets the go-ahead
APC 'capture index' measures airflow in the data center
Sun servers study Sun's energy at Princeton lab
Raised floor bests overhead cooling, IBM finds
Improved airflow cools off overheated data center

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
ambient temperature  (SearchDataCenter.com)
ASHRAE  (SearchDataCenter.com)
Calibrated Vectored Cooling  (SearchDataCenter.com)
compaction  (SearchDataCenter.com)
computer room air conditioning unit  (SearchDataCenter.com)
data center chiller  (SearchDataCenter.com)
green data center  (SearchDataCenter.com)
hot/cold aisle  (SearchDataCenter.com)
HVAC  (SearchDataCenter.com)
water cooling  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary



Efficient Management for Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts