HP's rack attack: Liquid cooling

By Matt Stansberry, News Editor
29 Jan 2006 | SearchDataCenter.com

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   

Today Hewlett-Packard joined the ranks of IBM and other server vendors by turning to liquid-based systems to ease server cooling headaches.

The HP Modular Cooling System (MCS) uses a building's existing chilled water supply to distribute cool air across the front of a standard HP 10000 G2 rack.
For more information:

Egenera rolls out new blades, liquid cooled chassis

Cool aid or Band-Aid?

HP claims that the MCS allows for the deployment of up to 30 kilowatts in a single rack. That's three times the amount of kilowatts that a standard server rack can handle according to Paul Perez, vice president, power and cooling at HP.

According to Perez, data centers haven't changed in 20 years, but IT requirements have, putting strain on cooling and power demand. Now, more companies are investing in liquid cooling to meet the requirements of denser, hotter machinery that can't be cooled by air alone.

HP has been investing research dollars in heat sinks, fans and software to curb the heat problem, but now there's a new sweet spot. "With water cooling you can now mount three times the processors in a rack, and customers won't need a raised floor," Perez said. "In the next two years, I predict there will be a standard for liquid distribution in the data center."

Experts agree traditional cooling will no longer cut it. "Intel chips run too damn hot," says Clay Ryder, president of Union City, Calif.-based Sageza. "If you look at performance gains over the past few years, they've come from putting more transistors on a die and pumping up the clock rate. Thermodynamics has caught up with us."

According to Ryder, pumping more electricity through a tighter circuit increases pressure and causes friction -- which translates into heat. But liquid has more conductive properties and is more efficient at cooling than air.

Six months ago, IBM unveiled a chilled water technology that hinges onto the back of an xSeries rack. And last week, Marlboro, Mass.-based blade specialists Egenera partnered with Columbus, Ohio-based Emerson Network Power to roll out a liquid refrigerant-cooled blade chassis.

Emerson and Egenera are both quick to point out that the Liebert XD system used in the Egnera blades is different from chilled water systems. Instead of water, the Liebert XD pumps liquid refrigerant (R134a) that is converted to a gas within the heat exchangers, and then it is returned to the pumping station where it is re-condensed to a liquid.

Ryder says water and liquid refrigerants have pros and cons:

  • Because a refrigerant changes phase from liquid to gas it's easier to pump than water, saving energy on pump efficiency.
  • Water is cheaper and easy to replace.
  • If water leaks it can damage equipment. If your refrigerant leaks, you won't have gallons on the floor, but your rack could burn up anyway.
  • Many rooms already have chilled water lines coming in and facility engineers are familiar with the systems.
  • The plumbing involved with water based systems make them less reconfigurable than refrigerant-based cooling that uses tubing and closed circuit systems.

    Perez claims the HP system has some differentiation over its competitors. "The MCS is general purpose and works across all of our families of servers. Egenera's product is designed to work for only its blades," Perez said. "And our water system runs at very low pressure, 15 PSI. IBM's Cool Blue runs much higher, around 60 PSI, and that eats up pump efficiency."

    Customers can install the MCS systems themselves if they have the expertise, or they can have HP install it as part of the company's recently announced data center assessment and design services.

    Critics of such programs suggest data center services from vendors such as Dell, HP and IBM are part of an agenda to sell products. Perez said he understands that concern and noted that the HP services are based on optimizing existing infrastructure -- but if it results in HP sales that's OK with him too.

    The HP chilled water cooling systems cost around $30,000 and are expected to be available Feb. 6.

    Let us know what you think about the story; e-mail: Matt Stansberry, News Editor



    Tags: Data center coolingNewsVIEW ALL TAGS

    Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


    << PREVIOUS | NEXT >>: Liquid-cooled refrigerants solve density hot spots
    VIEW ALL IN THIS CATEGORY


    RELATED CONTENT
    Data center cooling
    IT wish list: Better ways to analyze data center environmental metrics
    End users still cool on Iceland as a data center site
    Air-side economizers reduce energy use at NetApp data center
    Sizing computer room air conditioners for data center energy efficiency
    Should you comply with Article 645 of the National Electrical Code?
    How to identify and remediate data center hot spots
    Data center humidity levels source of debate
    Air-side and water-side economizers in the data center
    Amazon data center facility engineer touts radical cooling tactics
    Colo taps cold weather, river for green data center
    Data center cooling Research

    Data center power management
    Backup power in a shipping container: Active Power's PowerHouse
    U.S. Bowling Congress moves data center, halves energy costs
    Tom Friedman to data centers: 'Get ready for carbon tax'
    Google opts for battery backup over UPS: News in brief
    CRG West preps data centers for cloud computing customers
    ViaWest data centers go green, which makes dollars and cents
    Common data center hurdles: Cooling and power distribution problems
    Data center power consumption: Key theme at DCD
    Data center managers face mountains of technology shifts
    Welsh data center expected to be Europe's most advanced
    Data center power management Research

    News
    Server power and cooling experts offer engineering insight
    APC says it's time to beat the heat with water
    Water cooling takes center stage at Sun event
    Egenera rolls out new blades, liquid cooled chassis
    Liquid-cooled refrigerants solve density hot spots
    Liebert acquires Cooligy
    Cool Blue: How IBM beats the heat

    RELATED GLOSSARY TERMS
    Terms from Whatis.com − the technology online dictionary
    ambient temperature  (SearchDataCenter.com)
    ASHRAE  (SearchDataCenter.com)
    Calibrated Vectored Cooling  (SearchDataCenter.com)
    compaction  (SearchDataCenter.com)
    computer room air conditioning unit  (SearchDataCenter.com)
    data center chiller  (SearchDataCenter.com)
    green data center  (SearchDataCenter.com)
    hot/cold aisle  (SearchDataCenter.com)
    HVAC  (SearchDataCenter.com)
    water cooling  (SearchDataCenter.com)

    RELATED RESOURCES
    2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
    Search Bitpipe.com for the latest white papers and business webcasts
    Whatis.com, the online computer dictionary



  • Efficient Management for Data Centers
    HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
    About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
    SEARCH 
    TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

    TechTarget Corporate Web Site  |  Media Kits  |  Site Map




    All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
      TechTarget - The IT Media ROI Experts