Dry pre-action fire suppression systems

Lance Harry EXPERT RESPONSE FROM: Lance Harry

Pose a Question
Other Data Center Categories
Meet all Data Center Experts
Become an Expert for this site


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


>
QUESTION POSED ON: 02 November 2006
Can you explain a "dry pre-action" fire suppression system?


BROWSE BY TAG
Data center design and infrastructure,   Data center fire suppression,   Data center room design and location,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
Data center fire suppression
Drawbacks to hot/cold aisle containment
Hot-aisle/cold-aisle containment stokes fire-code issues
The Planet data center hosting company suffers major electrical fire
The data center EPO button: Is it even necessary?
NFPA 75: Raised floor fire protection
Halon and FM-200, part two
Selecting a sprinkler system: Dependent on local building code regulations?
Gas fire suppression systems
Water versus gas-based data center fire suppression
Seven steps to data center fire planning

Data center room design and location
Air-side economizers reduce energy use at NetApp data center
Data center location selection: Incentives can tip scales
Notes from AFCOM Data Center World: Day one
Microsoft cuts ribbon on mega data center
Hot-aisle/cold-aisle containment takes hold
How to identify and remediate data center hot spots
Colo taps cold weather, river for green data center
Preventing particle and gas contamination in the data center
Cleaning under the raised-floor plenum: Data center maintenance basics
AMD augments six-core Opteron chip line: News in brief
Data center room design and location Research

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
limited combustible cable  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary


As you have probably surmised, there are numerous 'types' of water based sprinkler systems. Generally, you can divide them into two groups, then subdivide beyond that: wet and dry systems.

A wet system is one in which there is always water present in the piping network of the system. When any given sprinkler head is burst (heats to a point where the thermal element is compromised), water will be discharged. Note that each sprinkler head acts independently in a sprinkler system; so all those movies and commercials you've seen where all the sprinklers go off at the same time?! Not accurate.

A dry system is one in which water is NOT present in the piping network all the time. A dry system includes a valve near the primary feed pipe of the water which is 'closed' until such time as it is required by the system.

A dry system requires some sort of action (thus the term pre-action) prior to actually flooding the pipe with water, and potentially discharging into the protected space. These actions typically come in a variety of ways and / or combinations:

  1. Smoke detection. Spot type smoke detectors are used to provide an alarm or signal to a central control panel that can then tell the valve connected to the water line to 'open'.
  2. Pressure switch. In some cases, the 'dry' or empty piping is actually pressurized with air or nitrogen. In a fire scenario, a given sprinkler head bursts, the pressure in the piping dissipates and the pressure switch is tripped. The tripped switch sends a signal to the control panel, and can then tell the valve to be opened, sending water throughout the piping network.

When BOTH the above actions are required for water to be discharged into the pipe network, that is generally referred to as a 'double interlock' or 'dual interlock' system. This type of strategy is common for sprinkler systems in high value asset areas like data centers.

You may want to use common web-based search tools for more information on this topic. There is plenty of data and text available 'out there'.




Search and Browse the Expert Answer Center
Search and browse more than 25,000 question and answer pairs from more than 250 TechTarget industry experts.
Browse our Expert Advice



Building Green Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts