What's the right fire suppression system for our small data center?

Robert McFarlane EXPERT RESPONSE FROM: Robert McFarlane

Pose a Question
Other Data Center Categories
Meet all Data Center Experts
Become an Expert for this site


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


>
QUESTION POSED ON: 26 October 2005
What is the correct fire suppression system to use for a small data center? Our data center currently consists of seven racks.


BROWSE BY TAG
Physical environment/power and cooling,   Data center design and infrastructure,   Data center fire suppression,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
Physical environment/power and cooling
Are energy-efficient KVMs next?
Powering modems with SMPS-based power supplies
Data center cooling and humidity control: CRAC or AHU?
Weighing centralized versus modular UPS in the data center
Overheating servers
UPS maintenance outage
More on power supplies
Dual power question
CRAC units with existing HVAC
Ideal data center components

Data center fire suppression
Drawbacks to hot/cold aisle containment
Hot-aisle/cold-aisle containment stokes fire-code issues
The Planet data center hosting company suffers major electrical fire
The data center EPO button: Is it even necessary?
Dry pre-action fire suppression systems
NFPA 75: Raised floor fire protection
Halon and FM-200, part two
Selecting a sprinkler system: Dependent on local building code regulations?
Gas fire suppression systems
Water versus gas-based data center fire suppression

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
limited combustible cable  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary


I doubt you will find anyone, other than a fire suppression system salesperson, who will tell you there is a "correct" solution for any data center. The liabilities if something unpredictable happens in a fire are just too high. All we can do is give the pros and cons of the different approaches and let you decide based on business risks, budget, local codes and often insurance requirements. I will be doing a blog on this next week, so I will give you a very brief answer here.

Water protects buildings and people. In most jurisdictions, it's required by code whether you have something more sophisticated or not. And if it's not required, your management -- and probably your insurer -- will want you to put it in anyway simply to avoid liability. The real question here is one of cost. "Dry pipe, pre-action" sprinklers avoid the risk of having pipes full of water running above your equipment, as well as the risk of a sprinkler head leaking or breaking, especially when no one is around. But in a data center of your size, it may be difficult to cost-justify pre-action, both in dollars and in the space for the valves and controls. Because your room is not large, I would check with your MEP engineer to see if the heads can be located on the walls, instead of in the ceiling. This, at least, would keep pipes and joints from being right above computer hardware.

The inert gas systems are meant to protect equipment. They react more quickly than sprinkler heads, which don't open until flames have actually raised the temperature enough to open them. By then you have a pretty good fire going. Inert gas actually gets into the cabinets and equipment and either absorbs the heat or deprives the fire of oxygen, depending on the product used. Obviously, if the gas puts out the fire at the source before it spreads, it also protects people and the structure, but most codes don't look at it that way. Code authorities are concerned about what happens if the fire does not go out, or if it reignites after the gas has been dumped. Hence, the requirement for sprinklers no matter what else you may have -- even if you have "reserve tanks" of suppressant.

Gas-based systems depend on the volume of the room, which in your case would seem to be quite small. This could probably be handled with wall-mounted gas cylinders, rather than a fully piped installation. This would be much less expensive. But the hidden cost in an inert gas solution is what must be done in the room construction. Everything must be sealed. Every duct going through the room must have automatic fire dampers. There must be alarms, automatic shutdowns of power and air conditioners, control systems with smoke detectors and enunciator panels, etc. Even the ceiling tiles must be clipped down to keep them from being blown out by the force of the gas release, which is quite dramatic.

In short, there is no "correct solution." But hopefully this will give you a little better idea of what you need to be aware of in deciding what's best, and most justifiable, for you.




Search and Browse the Expert Answer Center
Search and browse more than 25,000 question and answer pairs from more than 250 TechTarget industry experts.
Browse our Expert Advice



Building Green Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts