Monitoring temperature in the data center

Robert McFarlane EXPERT RESPONSE FROM: Robert McFarlane

Pose a Question
Other Data Center Categories
Meet all Data Center Experts
Become an Expert for this site


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


>
QUESTION POSED ON: 14 July 2005
How do I report the cooling consumption of a data center on a daily, weekly and monthly basis? This report will help the IT facilities managers make decisions on when to add or remove cooling (humidification) from the data center. Also, is it possible to ensure stable cooling in the data center 24 hours a day, 7 days a week, 365 days per year?

>

You can't realistically measure and quantify cooling consumption. There are two things you can do, however, to achieve your goal:

  1. Monitor and record power consumption, which is the major variable that correlates to cooling requirements. (Assuming you're not in the outside corner of a building with big windows and poor insulation, the Summer/Winter difference won't be your major variable.) The more specifically you can monitor, the better, right down to individual cabinet power strips, which are now available with both local and remote metering. This will also help you maintain load balance on dual UPS's and phase balance on 3-phase circuits, both of which contribute significantly to power stability. Every 3,000 Watts (approximately 25 amps at 120 volts) requires 10,200 BTU of sensible cooling. If you're using conventional Computer Room Air Conditioners (CRAC's) with humidification, set for 72F Return Air; this will require about one ton of total machine capacity. These are very "round numbers" but should give you a good guideline.

  2. Install temperature and humidity monitors at key locations in the room and at least in each "High-Density" cabinet, although every cabinet is preferable. There are many systems now available to do this. The system won't tell you how much cooling you need, (the power measurements will,) but will certainly identify when and where cooling is needed, and whether or not the air conditioning additions you made were effective. This will also help you get the most from the air conditioning you already have. If it saves installing just one CRAC unit, the monitors will more than pay for themselves. Additionally, the information provided will be a very good way to know if your cooling design remains stable under all conditions.


BROWSE BY TAG
Physical environment/power and cooling,   Data center design and infrastructure,   Data center cooling,   Data center design and infrastructure,   Chapter 3: Data center cooling,   Data center cooling metrics and design,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
Physical environment/power and cooling
Are energy-efficient KVMs next?
Powering modems with SMPS-based power supplies
Data center cooling and humidity control: CRAC or AHU?
Weighing centralized versus modular UPS in the data center
Overheating servers
UPS maintenance outage
More on power supplies
Dual power question
CRAC units with existing HVAC
Ideal data center components

Data center cooling
IT wish list: Better ways to analyze data center environmental metrics
End users still cool on Iceland as a data center site
Air-side economizers reduce energy use at NetApp data center
Sizing computer room air conditioners for data center energy efficiency
Should you comply with Article 645 of the National Electrical Code?
How to identify and remediate data center hot spots
Data center humidity levels source of debate
Air-side and water-side economizers in the data center
Amazon data center facility engineer touts radical cooling tactics
Colo taps cold weather, river for green data center
Data center cooling Research

Data center cooling metrics and design
Improved airflow cools off overheated data center
Fears of cooling with outside air may be unfounded
Using ASHRAE specs for data center metrics
How do I measure cooling consumption?
The total cost of cooling
What's the best way to install a wall vapor barrier?
Cooling data centers: A look toward the future
New cooling technologies could cut energy costs
Cooler rooms or cooler servers?

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
ambient temperature  (SearchDataCenter.com)
ASHRAE  (SearchDataCenter.com)
Calibrated Vectored Cooling  (SearchDataCenter.com)
compaction  (SearchDataCenter.com)
computer room air conditioning unit  (SearchDataCenter.com)
data center chiller  (SearchDataCenter.com)
green data center  (SearchDataCenter.com)
hot/cold aisle  (SearchDataCenter.com)
HVAC  (SearchDataCenter.com)
water cooling  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary



Search and Browse the Expert Answer Center
Search and browse more than 25,000 question and answer pairs from more than 250 TechTarget industry experts.
Browse our Expert Advice



Building Green Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts