How to figure size requirements for new UPS unit

Robert McFarlane EXPERT RESPONSE FROM: Robert McFarlane

Pose a Question
Other Data Center Categories
Meet all Data Center Experts
Become an Expert for this site


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


>
QUESTION POSED ON: 20 January 2005
We need a new UPS, but we're confused by how to figure the size. Some ratings are in kW and kVA, others in only kVA or kW. Some have the same kW and kVA ratings, but for most the numbers are different. Then we have equipment rated in watts, VA or kVA, and some with just volts and amps ? often with a range of values. We don't want to over- or under-buy. What does it all mean?


BROWSE BY TAG
Physical environment/power and cooling,   Data center design and infrastructure,   Data center power management,   Data center backup power,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


RELATED CONTENT
Physical environment/power and cooling
Are energy-efficient KVMs next?
Powering modems with SMPS-based power supplies
Data center cooling and humidity control: CRAC or AHU?
Weighing centralized versus modular UPS in the data center
Overheating servers
UPS maintenance outage
More on power supplies
Dual power question
CRAC units with existing HVAC
Ideal data center components

Data center power management
Backup power in a shipping container: Active Power's PowerHouse
U.S. Bowling Congress moves data center, halves energy costs
Tom Friedman to data centers: 'Get ready for carbon tax'
Google opts for battery backup over UPS: News in brief
CRG West preps data centers for cloud computing customers
ViaWest data centers go green, which makes dollars and cents
Common data center hurdles: Cooling and power distribution problems
Data center power consumption: Key theme at DCD
Data center managers face mountains of technology shifts
Welsh data center expected to be Europe's most advanced
Data center power management Research

Data center backup power
Backup power in a shipping container: Active Power's PowerHouse
Using flywheel power for data center uninterruptible power supply backup
Uninterruptible power supply load bus synchronization: Yes or no?
Do dual-power supply servers increase redundancy?
Flywheel UPS, not batteries, for data center company's backup power
Data center shaves 10% off yearly electric bill
Weighing centralized versus modular UPS in the data center
Uptime Institute warns against tier standard misuse
UPS maintenance outage
More on power supplies

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
Electric plugs for each country  (SearchDataCenter.com)
green data center  (SearchDataCenter.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary


The difference between watts (W) and volt-amperes (VA) confuses everyone, so don't feel alone. (kW and kVA simply mean 1,000 watts or 1,000 volt-amperes – the "kilo" prefix being used for larger numbers.) The basic rule of physics that "watts = volts x amps" is based on direct current (DC) circuits. Alternating current (AC), which supplies our buildings and equipment, is more efficient for the power company to deliver, but when it hits the transformers (coils of wire or inductors) inside most of our technology, it exhibits a characteristic known as reactance. Reactance reduces the useful power (watts) available from the apparent power (volt-amperes). The ratio of these two numbers is called the power factor (pf). Therefore, the actual power formula for AC circuits is "watts = volts x amps x power factor." Unfortunately, the power factor is rarely stated for most equipment, but it is always a number of 1.0 or less, and about the only thing with a 1.0 pf is a light bulb.

For years, large UPS Systems have been designed based on a pf of 0.8, which means that a 100 kVA UPS will only support 80 kW of "real" power load. Most UPSes continue to be designed that way, even though the majority of technology today has power factors of 0.95 – 0.98. (This is mainly because Europe won't allow anything with a pf less than 0.95 to be sold.) Neither the kW nor the kVA capacity of the UPS can be exceeded, but because of the higher pf numbers, it is usually the kW rating that governs today. There are, however, some UPSes on the market that are power factor corrected so that the kW and kVA ratings are the same.

The biggest problem is determining actual load, since many data hardware manufacturers still provide very inadequate or erroneous power data on their equipment. For the bigger manufacturers, investigate configurator web sites, which tend to give quite accurate information. But if you're forced to use the nameplate data on the devices, beware! This is a legality rating, and will usually give a much higher volt-ampere rating than the unit will ever draw. Consider a unit with a nameplate that reads 90 – 240 volts at 4 – 8 amps, and has a 500 watt power supply. First, the numbers are backwards. The larger amperage goes with the lower voltage. If you assume a nominal 120 volts at 8 amps, you get 960 VA. A pf of 0.95 would yield 912 watts. No power supply is that inefficient, and a power supply almost never runs at full power. Therefore, it is highly unlikely that this device will ever draw more than 500 watts of power, but if you want to be really conservative, multiply by 1.1 and figure 550 watts of input power. And don't get trapped by dual-corded equipment. The power supplies share the load and either one is supposed to be able to carry the full load. Therefore, a unit with two 500 watt supplies should still be figured as if it had only one.




Search and Browse the Expert Answer Center
Search and browse more than 25,000 question and answer pairs from more than 250 TechTarget industry experts.
Browse our Expert Advice



Building Green Data Centers
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts